DMMS IEC 60335-2-74; 2006 Household and similar electrical appliances – Safety – Part 2-74: Particular requirements for portable immersion heaters |
|
TC1-Technical Committee for Electrical and Electronic |
|
|
|
19 |
DMMS IEC 60335-2-73 : 2006 Household and similar electrical appliances – Safety- Part 2-73: Particular requirements for fixed immersion heaters |
|
TC1-Technical Committee for Electrical and Electronic |
|
|
|
18 |
DMMS IEC 60335-2-65 : 2008 Household and similar electrical appliances – Safety- Part 2-65: Particular requirements for air-cleaning appliances |
|
TC1-Technical Committee for Electrical and Electronic |
|
|
|
17 |
DMMS IEC 60335-2-56 : 2008 Household and similar electrical appliances – Safety- Part 2-56: Particular requirements for projectors and similar appliances |
|
TC1-Technical Committee for Electrical and Electronic |
|
|
|
16 |
DMMS IEC 60335-2-55 : 2008 Household and similar electrical appliances – Safety- Part 2-55: Particular requirements for electrical appliances for use with aquariums and garden ponds |
|
TC1-Technical Committee for Electrical and Electronic |
|
|
|
15 |
DMMS IEC 60335-2-52 : 2008 Household and similar electrical appliances – Safety- Part 2-52: Particular requirements for oral hygiene appliances |
|
TC1-Technical Committee for Electrical and Electronic |
|
|
|
14 |
DMMS IEC 60335-2-45 : 2008 Household and similar electrical appliances – Safety- Part 2-45: Particular requirements for portable heating tools and similar appliances |
|
TC1-Technical Committee for Electrical and Electronic |
|
|
|
13 |
DMMS IEC 60335-2-31 : 2012 Household and similar electrical appliances – Safety- Part 2-31: Particular requirements for range hoods and other cooking fume extractors |
|
TC1-Technical Committee for Electrical and Electronic |
|
|
|
12 |
DMMS IEC 60335-2-29 : 2016 Household and similar electrical appliances – Safety- Part 2-29: Particular requirements for battery chargers |
|
TC1-Technical Committee for Electrical and Electronic |
|
|
|
11 |
DMMS IEC 60335-2-28 : 2008 Household and similar electrical appliances – Safety- Part 2-28: Particular requirements for sewing machines |
|
TC1-Technical Committee for Electrical and Electronic |
|
|
|
10 |
DMMS IEC 60335-2-21 : 2012 Household and similar electrical appliances – Safety- Part 2-21: Particular requirements for storage water heaters |
|
TC1-Technical Committee for Electrical and Electronic |
|
|
|
9 |
DMMS IEC 60335-2-8 : 2012 Household and similar electrical appliances – Safety- Part 2-8: Particular requirements for shavers, hair clippers and similar appliances |
|
TC1-Technical Committee for Electrical and Electronic |
|
|
|
8 |
DMMS IEC 60335-2-6 : 2014 Household and similar electrical appliances – Safety- Part 2-6: Particular requirements for stationary cooking ranges, hobs, ovens and similar appliances |
|
TC1-Technical Committee for Electrical and Electronic |
|
|
|
7 |
DMMS IEC 60335-2-2 : 2009 Household and similar electrical appliances – Safety- Part 2-2: Particular requirements for vacuum cleaners and water-suction cleaning appliances |
|
TC1-Technical Committee for Electrical and Electronic |
|
|
|
6 |
DMMS IEC 60228 : 2004 Conductors of insulated cables |
This International Standard specifies the nominal cross-sectional areas in the range 0,5 mm2 to 2500 mm2, for conductors in electric power cables and cords of a wide range of types. Requirements for numbers and sizes of wires and resistance values are also included. These conductors include solid and stranded copper, aluminum and aluminum alloy conductors in cables for fixed installations and flexible copper conductors.
The standard does not apply to conductors for telecommunication purposes.
The applicability of this standard to a particular type of cable is as specified in the standard for the type of cable.
Unless indicated to the contrary in a particular clause, this standard related to the conductors in the finished cable and not to the conductor as made or supplied for inclusion into a cable.
Informative annexes are included giving supplementary information covering temperature correction factors for resistance measurement (Annex B) and dimensional limits of circular conductors (Annex C) |
TC1-Technical Committee for Electrical and Electronic |
|
|
|
5 |
DMMS IEC 60227- 6 : 2001 Polyvinyl chloride insulated cables of rated voltage up to and including 450/750V – Part – 6 Lift cables and cables for flexible connections |
This part of IEC 60227 details the particular specifications for both circular and flat lift cables and cables for flexible connections of rated voltages up to and including 450/750V.
Each cable complies with the appropriate requirements given in IEC 60227-0 and with the particular requirements of this part IEC 60227. |
TC1-Technical Committee for Electrical and Electronic |
|
|
|
4 |
DMMS IEC 60227- 2 : 1997 Polyvinyl chloride insulated cables of rated voltage up to and including 450/750V – Part 2 : Test Methods |
General requirements: The methods of carrying out the tests specified in all parts of IEC 60227 are given in this part and the following publications.
IEC 60227-1:1993 Polyvinyl chloride insulted cables of rated voltages up to and including 450/750 V – Part 1 : General requirements
IEC 60332-1 : Tests on electric cables under fire conditions- Part 1- Test on a single vertical insulated cable
IEC 60811-1-1:1993, Common test methods for insulation and sheathing materials of electrical cables – Part 1 : Methods for general application – Section 1 : Measurement of thickness and overall dimensions – Test for determining the mechanical properties |
TC1-Technical Committee for Electrical and Electronic |
|
|
|
3 |
DMMS IEC 60227-4 : 1997 Polyvinyl chloride insulated cable of rate voltage up to and including 450/750V-Part 4 : Sheathed cables for fixed wiring |
This part of IEC 227 details the particular specifications for light polyvinyl chloride sheathed cables of rated voltage of 300/500 V.
Each cable shall comply with the appropriate requirements given in IEC 227-1 and the particular requirements of this part. |
TC1-Technical Committee for Electrical and Electronic |
|
|
|
2 |
DMMS IEC 60227-3 : 1997 Polyvinyl chloride insulated cables of rated voltage up to and including 450/750V- Part 3: Non – sheathed cables for fixed wiring |
This part of IEC 227 details the particular specifications for polyvinyl chloride insulated single – core non-sheathed cables for fixed wiring of rated voltages up to and including 450/750 V.
All cables shall comply with the appropriate requirements given in IEC 227-1 and the individual types of cables shall each comply with the particular requirements of this part. |
TC1-Technical Committee for Electrical and Electronic |
|
|
|
1 |
DMMS IEC 60227-1 : 2007 Polyvinyl chloride insulated cables of rated voltage up to and including 450/750V- Part 1 : General requirements |
This part of International Standards IEC 60227 applies to rigid and flexible cables with insulation and sheath if any based on polyvinyl chloride of rated voltages U0/U up to and including 450/750V used in power installations of nominal voltage not exceeding 450/750 V a.c.Note For some types of flexible cables the term cord is used.
The particular types of cables are specified in IEC 60227-3, 60227-4, etc. The code designations of these types of cables are given in Annex A.The test methods specified in Parts 1.3,4, etc. are given in IEC 60227-2, 60332-1-2 and in the relevant parts of IEC 60811. |
TC1-Technical Committee for Electrical and Electronic |
|
|
|